Weiss SD 1400/+20 DU climate test chamber with seat pulsator, 20 - 100 °C heating chamber, humidity Weiss
SD 1400/+20 DU
Weiss SD 1400/+20 DU climate test chamber with seat pulsator, 20 - 100 °C heating chamber, humidity
Weiss
SD 1400/+20 DU
Vraagprijs excl. btw
€ 16.638
Toestand
Gebruikt
Locatie
Borken 

Basisgegevens
- Machinetype:
- Weiss SD 1400/+20 DU climate test chamber with seat pulsator, 20 - 100 °C heating chamber, humidity
- Producent:
- Weiss
- Model:
- SD 1400/+20 DU
- Toestand:
- gebruikt
Prijs & locatie
Vraagprijs excl. btw
€ 16.638
- Locatie:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Bellen
Details over het aanbod
- Advertentie-ID:
- A199-61285
- Referentienummer:
- 48551
- Laatste aanpassing:
- voor het laatst op 21.10.2026
Omschrijving
Weiss climate testing chamber with seat pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Volume: 1440 liters
Outer housing
Blodpfx Aexbgrgskqsp
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint: light gray (RAL 9002)
Door, double-leaf: hinged on the left and right
Equipment:
Passage through the floor and ceiling: 2 pieces each, nominal diameter 100 mm, for installing the pulsation table
Passage in the side walls: 1 piece each, left, right, 100 mm
Refrigeration unit: air-cooled
Control: Digital measuring and control system DMR
Basic control panel: integrated in the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS-Windows
Performance data:
Temperature range without climate control: +20...+100 °C
Temperature stability without climate control: +0.2 … ±0.5 K (time-dependent) depending on the range, in the stable state
Temperature range with climate control: 20...+95 °C
Temperature stability with climate control: +0.2 … +0.5 K (time-dependent) depending on the range, in the stable state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH, depending on the range, in the stable state
Temperature change rate measured in the outlet without test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
- Heating: 0.5 K/min on average, between +20 and +100 °C
The performance data refer to an ambient temperature of max. +25 °C and the specified rated voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Connections / Other
Protection class: IP 32 for the control cabinet
Sound pressure level during free-field measurement at a distance of 1 m in front of the device: 60 dB (A)
Humidification water: fully demineralized, conductivity max. 20 μS/cm, pH value 6 - 7, automatic replenishment
Condensate drain: backpressure-free, 3/4" hose connection
Mains connection: 400 V; 3 PH+N PE; 50 Hz
Connection value: max. 10 kVA
Weight: approx. 1160 kg
Seat testing device with steel structure for mounting and securing to the climate testing chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for test specimen changeover, 12 weights each with 5 kg
• 1 base frame in normal steel welded construction for fastening to the underside of the climate testing chamber. This frame is equipped with removable sheets on all sides and has 2 folding doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric disks with bearing and tachometer, 2 connecting rods, 2 ball guides
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for connecting the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for connecting the buttock simulation
• 2 load rods, 600 mm long, made of stainless steel (The connection to the test specimen is not included in our price, but can be offered at a later date after a precise definition.)
• 2 three-phase motors, 2 belt drives with tensioning devices
• 1 pneumatic control with 2 hand valves, a filter-regulator unit and a shut-off valve, 1 electrical control cabinet with 2 SEW frequency inverters, hand switch, emergency stop button, 2 push buttons, 2 release buttons, 2 speed indicators, 2 potentio
De advertentie werd automatisch vertaald. Vertaalfouten zijn mogelijk.
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Volume: 1440 liters
Outer housing
Blodpfx Aexbgrgskqsp
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint: light gray (RAL 9002)
Door, double-leaf: hinged on the left and right
Equipment:
Passage through the floor and ceiling: 2 pieces each, nominal diameter 100 mm, for installing the pulsation table
Passage in the side walls: 1 piece each, left, right, 100 mm
Refrigeration unit: air-cooled
Control: Digital measuring and control system DMR
Basic control panel: integrated in the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS-Windows
Performance data:
Temperature range without climate control: +20...+100 °C
Temperature stability without climate control: +0.2 … ±0.5 K (time-dependent) depending on the range, in the stable state
Temperature range with climate control: 20...+95 °C
Temperature stability with climate control: +0.2 … +0.5 K (time-dependent) depending on the range, in the stable state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH, depending on the range, in the stable state
Temperature change rate measured in the outlet without test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
- Heating: 0.5 K/min on average, between +20 and +100 °C
The performance data refer to an ambient temperature of max. +25 °C and the specified rated voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Connections / Other
Protection class: IP 32 for the control cabinet
Sound pressure level during free-field measurement at a distance of 1 m in front of the device: 60 dB (A)
Humidification water: fully demineralized, conductivity max. 20 μS/cm, pH value 6 - 7, automatic replenishment
Condensate drain: backpressure-free, 3/4" hose connection
Mains connection: 400 V; 3 PH+N PE; 50 Hz
Connection value: max. 10 kVA
Weight: approx. 1160 kg
Seat testing device with steel structure for mounting and securing to the climate testing chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for test specimen changeover, 12 weights each with 5 kg
• 1 base frame in normal steel welded construction for fastening to the underside of the climate testing chamber. This frame is equipped with removable sheets on all sides and has 2 folding doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric disks with bearing and tachometer, 2 connecting rods, 2 ball guides
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for connecting the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for connecting the buttock simulation
• 2 load rods, 600 mm long, made of stainless steel (The connection to the test specimen is not included in our price, but can be offered at a later date after a precise definition.)
• 2 three-phase motors, 2 belt drives with tensioning devices
• 1 pneumatic control with 2 hand valves, a filter-regulator unit and a shut-off valve, 1 electrical control cabinet with 2 SEW frequency inverters, hand switch, emergency stop button, 2 push buttons, 2 release buttons, 2 speed indicators, 2 potentio
De advertentie werd automatisch vertaald. Vertaalfouten zijn mogelijk.
Aanbieder
Opmerking: Registreer gratis of log in, om alle informatie te bekijken.
Geregistreerd sinds: 2008
529 advertenties online
Aanvraag sturen
Telefoon & Fax
+49 2862 ... weergeven
Uw advertentie is succesvol verwijderd
Er is een fout opgetreden